| Id |
Subject |
Object |
Predicate |
Lexical cue |
| TextSentencer_T1 |
0-117 |
Sentence |
denotes |
Failure of Polyethelene Insert Locking Mechanism after a Posterior Stabilised Total Knee Arthroplasty- A Case Report. |
| T1 |
0-117 |
Sentence |
denotes |
Failure of Polyethelene Insert Locking Mechanism after a Posterior Stabilised Total Knee Arthroplasty- A Case Report. |
| TextSentencer_T2 |
118-131 |
Sentence |
denotes |
INTRODUCTION: |
| T2 |
118-131 |
Sentence |
denotes |
INTRODUCTION: |
| TextSentencer_T3 |
132-236 |
Sentence |
denotes |
Disengagement of polyethylene insert used in total knee arthroplasty is a rare but serious complication. |
| T3 |
132-236 |
Sentence |
denotes |
Disengagement of polyethylene insert used in total knee arthroplasty is a rare but serious complication. |
| TextSentencer_T4 |
237-320 |
Sentence |
denotes |
Still rarer is disengagement because of failure of tibial insert locking mechanism. |
| T4 |
237-320 |
Sentence |
denotes |
Still rarer is disengagement because of failure of tibial insert locking mechanism. |
| TextSentencer_T5 |
321-571 |
Sentence |
denotes |
We report a previously unpublished complication of polyethylene insert locking mechanism failure in a 10-months-old posterior stabilized total knee arthroplasty in a 70-year-old woman with osteoarthritis for whom Attune (Depuy) knee implant was used. |
| T5 |
321-571 |
Sentence |
denotes |
We report a previously unpublished complication of polyethylene insert locking mechanism failure in a 10-months-old posterior stabilized total knee arthroplasty in a 70-year-old woman with osteoarthritis for whom Attune (Depuy) knee implant was used. |
| TextSentencer_T6 |
572-590 |
Sentence |
denotes |
CASE PRESENTATION: |
| T6 |
572-590 |
Sentence |
denotes |
CASE PRESENTATION: |
| TextSentencer_T7 |
591-723 |
Sentence |
denotes |
A 70-year-old female underwent (Attune, Depuy) primary bilateral posterior stabilised total knee arthroplasty in a private hospital. |
| T7 |
591-723 |
Sentence |
denotes |
A 70-year-old female underwent (Attune, Depuy) primary bilateral posterior stabilised total knee arthroplasty in a private hospital. |
| TextSentencer_T8 |
724-820 |
Sentence |
denotes |
The patient did not have any complaints and had had been functioning well post her arthroplasty. |
| T8 |
724-820 |
Sentence |
denotes |
The patient did not have any complaints and had had been functioning well post her arthroplasty. |
| TextSentencer_T9 |
821-958 |
Sentence |
denotes |
After five months of surgery she had a fall and sustained injury over right hip which was treated with Cemented Bipolar Hemiarthroplasty. |
| T9 |
821-958 |
Sentence |
denotes |
After five months of surgery she had a fall and sustained injury over right hip which was treated with Cemented Bipolar Hemiarthroplasty. |
| TextSentencer_T10 |
959-1141 |
Sentence |
denotes |
Ten months after index surgery, she sustained trivial fall and presented to the same hospital with knee pain and swelling, where the right knee prosthesis was found to be dislocated. |
| T10 |
959-1141 |
Sentence |
denotes |
Ten months after index surgery, she sustained trivial fall and presented to the same hospital with knee pain and swelling, where the right knee prosthesis was found to be dislocated. |
| TextSentencer_T11 |
1142-1308 |
Sentence |
denotes |
An attempted closed reduction under anaesthesia failed, after which she was referred to our centre with an unstable, painful, swollen right knee in a long knee brace. |
| T11 |
1142-1308 |
Sentence |
denotes |
An attempted closed reduction under anaesthesia failed, after which she was referred to our centre with an unstable, painful, swollen right knee in a long knee brace. |
| TextSentencer_T12 |
1309-1506 |
Sentence |
denotes |
The physical examination at the time of admission showed posterior sag of the tibia, fullness in the postero-lateral corner, quadriceps muscle atrophy without any neurovascular deficit oflower leg. |
| T12 |
1309-1506 |
Sentence |
denotes |
The physical examination at the time of admission showed posterior sag of the tibia, fullness in the postero-lateral corner, quadriceps muscle atrophy without any neurovascular deficit oflower leg. |
| TextSentencer_T13 |
1507-1566 |
Sentence |
denotes |
Postero-lateral dislocation was confirmed with radiographs. |
| T13 |
1507-1566 |
Sentence |
denotes |
Postero-lateral dislocation was confirmed with radiographs. |
| TextSentencer_T14 |
1567-1682 |
Sentence |
denotes |
Surgical error as a possible causative factor was excluded because patient had been functioning well after surgery. |
| T14 |
1567-1682 |
Sentence |
denotes |
Surgical error as a possible causative factor was excluded because patient had been functioning well after surgery. |
| TextSentencer_T15 |
1683-1740 |
Sentence |
denotes |
Her comorbidities included hypertension and hyponatremia. |
| T15 |
1683-1740 |
Sentence |
denotes |
Her comorbidities included hypertension and hyponatremia. |
| TextSentencer_T16 |
1741-1779 |
Sentence |
denotes |
ESR and CRP were within normal limits. |
| T16 |
1741-1779 |
Sentence |
denotes |
ESR and CRP were within normal limits. |
| TextSentencer_T17 |
1780-1818 |
Sentence |
denotes |
An open reduction surgery was planned. |
| T17 |
1780-1818 |
Sentence |
denotes |
An open reduction surgery was planned. |
| TextSentencer_T18 |
1819-1897 |
Sentence |
denotes |
On exposure, polyethylene was found in the postero-lateral corner of the knee. |
| T18 |
1819-1897 |
Sentence |
denotes |
On exposure, polyethylene was found in the postero-lateral corner of the knee. |
| TextSentencer_T19 |
1898-2099 |
Sentence |
denotes |
We were not sure that revising the polyethylene alone would suffice as the poly and locking mechanism was of a relatively new design and hence it was decided to proceed with revision of the components. |
| T19 |
1898-2099 |
Sentence |
denotes |
We were not sure that revising the polyethylene alone would suffice as the poly and locking mechanism was of a relatively new design and hence it was decided to proceed with revision of the components. |
| TextSentencer_T20 |
2100-2222 |
Sentence |
denotes |
Revision was done with stemmed components, distal femoral augments and a constrained prosthesis (Total Condylar 3, Depuy). |
| T20 |
2100-2222 |
Sentence |
denotes |
Revision was done with stemmed components, distal femoral augments and a constrained prosthesis (Total Condylar 3, Depuy). |
| TextSentencer_T21 |
2223-2261 |
Sentence |
denotes |
Intraoperative cultures were negative. |
| T21 |
2223-2261 |
Sentence |
denotes |
Intraoperative cultures were negative. |
| TextSentencer_T22 |
2262-2317 |
Sentence |
denotes |
The patient had an uncomplicated post-operative course. |
| T22 |
2262-2317 |
Sentence |
denotes |
The patient had an uncomplicated post-operative course. |
| TextSentencer_T23 |
2318-2329 |
Sentence |
denotes |
CONCLUSION: |
| T23 |
2318-2329 |
Sentence |
denotes |
CONCLUSION: |
| TextSentencer_T24 |
2330-2481 |
Sentence |
denotes |
Disengagement of polyethylene should be considered as a differential diagnosis in patients who present with acute swelling and instability of the knee. |
| T24 |
2330-2481 |
Sentence |
denotes |
Disengagement of polyethylene should be considered as a differential diagnosis in patients who present with acute swelling and instability of the knee. |
| TextSentencer_T25 |
2482-2633 |
Sentence |
denotes |
Though it's a rare complication, there is a possibility that design of the implant or its locking mechanism could contribute to dislocations in future. |
| T25 |
2482-2633 |
Sentence |
denotes |
Though it's a rare complication, there is a possibility that design of the implant or its locking mechanism could contribute to dislocations in future. |