| Id |
Subject |
Object |
Predicate |
Lexical cue |
| TextSentencer_T1 |
0-158 |
Sentence |
denotes |
Diagnosis of intraventricular cysticercosis by magnetic resonance imaging: improved detection with three-dimensional spoiled gradient recalled echo sequences. |
| T1 |
0-158 |
Sentence |
denotes |
Diagnosis of intraventricular cysticercosis by magnetic resonance imaging: improved detection with three-dimensional spoiled gradient recalled echo sequences. |
| TextSentencer_T2 |
159-273 |
Sentence |
denotes |
Neurocysticercosis (NCC) is caused when the cysticercus larvae of Taenia solium infect the central nervous system. |
| T2 |
159-273 |
Sentence |
denotes |
Neurocysticercosis (NCC) is caused when the cysticercus larvae of Taenia solium infect the central nervous system. |
| TextSentencer_T3 |
274-396 |
Sentence |
denotes |
The larvae usually land in the parenchymal tissue, but quite rarely can lodge in the ventricles and cisterns of the brain. |
| T3 |
274-396 |
Sentence |
denotes |
The larvae usually land in the parenchymal tissue, but quite rarely can lodge in the ventricles and cisterns of the brain. |
| TextSentencer_T4 |
397-511 |
Sentence |
denotes |
Unlike parenchymal NCC, it is not easy to demonstrate the cysticercus cysts within the cerebrospinal fluid spaces. |
| T4 |
397-511 |
Sentence |
denotes |
Unlike parenchymal NCC, it is not easy to demonstrate the cysticercus cysts within the cerebrospinal fluid spaces. |
| TextSentencer_T5 |
512-597 |
Sentence |
denotes |
Computed tomography and even conventional MR sequences can fail to detect such cysts. |
| T5 |
512-597 |
Sentence |
denotes |
Computed tomography and even conventional MR sequences can fail to detect such cysts. |
| TextSentencer_T6 |
598-803 |
Sentence |
denotes |
However, obtaining three-dimensional spoiled gradient recalled echo imaging sequences can help in improving the detection of intraventricular NCC, as is borne out by a case described in the present report. |
| T6 |
598-803 |
Sentence |
denotes |
However, obtaining three-dimensional spoiled gradient recalled echo imaging sequences can help in improving the detection of intraventricular NCC, as is borne out by a case described in the present report. |
| TextSentencer_T7 |
804-916 |
Sentence |
denotes |
The use of such special MR sequences is therefore strongly advocated in suspected cases of intraventricular NCC. |
| T7 |
804-916 |
Sentence |
denotes |
The use of such special MR sequences is therefore strongly advocated in suspected cases of intraventricular NCC. |