PMC:7574920 / 48085-49301 JSONTXT 8 Projects

Annnotations TAB TSV DIC JSON TextAE

Id Subject Object Predicate Lexical cue
T348 0-66 Sentence denotes To prevent cross-contamination, we have taken several precautions.
T349 67-173 Sentence denotes The 10× primer mix was prepared with nuclease-free water (AM9937, Ambion) and stored in aliquots at −20°C.
T350 174-342 Sentence denotes To set up an RT-LAMP test, the RT-LAMP master mix was prepared freshly immediately before the test at a separate workspace with a dedicated pipette set and filter tips.
T351 343-463 Sentence denotes The 96-well PCR plate containing the RT-LAMP mix was covered with an Society for Biomolecular Screening (SBS) plate lid.
T352 464-609 Sentence denotes To avoid mix-ups during sample addition through well-by-well pipetting, the RNA or swab specimens were first collected into a 96-well seed plate.
T353 610-781 Sentence denotes The RNA was then added to the plate with the LAMP reagents at a dedicated workspace with a manual 96-channel pipettor (Liquidator 20 μl, Mettler Toledo) using filter tips.
T354 782-1001 Sentence denotes The RT-LAMP and the RNA seed plate were instantly sealed with an optically clear adhesive seal (GK480-OS, Kisker Biotech) and an adhesive aluminum foil seal (SL-AM0550, Steinbrenner Laborsysteme, Germany), respectively.
T355 1002-1216 Sentence denotes If the product of an RT-LAMP reaction had to be analyzed by gel electrophoresis, the plate was opened with extreme caution at a separated post-LAMP workspace and loaded onto an agarose gel with a dedicated pipette.