T253 0-163 Sentence denotes We tested the RT-LAMP primer sets suggested by Zhang et al. (11) and found that the N-A primer set for the N gene worked better than the 1a-A primer set for ORF1a.
T254 164-432 Sentence denotes For samples with a CT ≤ 30 as measured by RT-qPCR with E-Sarbeco primers, we found overall satisfactory sensitivity and specificity values for SARS-CoV-2 RNA detection by the RT-LAMP assay using RNA samples isolated from pharyngeal swab specimens (Fig. 3 and Table 1).
T255 433-501 Sentence denotes For samples with CT > 30, the RT-LAMP assay was much less sensitive.
T256 502-619 Sentence denotes However, there is debate about which CT value for a positive RT-qPCR result should be considered clinically relevant.
T257 620-718 Sentence denotes Vogels et al. (16) indicate that a CT value above 36 corresponds to less than 10 molecules of RNA.