Id |
Subject |
Object |
Predicate |
Lexical cue |
T77 |
0-53 |
Sentence |
denotes |
Cleaning and disinfection of radiology equipment [11] |
T78 |
55-69 |
Sentence |
denotes |
Daily cleaning |
T79 |
70-72 |
Sentence |
denotes |
I. |
T80 |
73-171 |
Sentence |
denotes |
Metal surface and painted surface can be wiped with soft detergent, and then dried with dry towel. |
T81 |
172-265 |
Sentence |
denotes |
Corrosive cleaning agent, corrosive detergent, and corrosive polishing agent are not allowed. |
T82 |
266-269 |
Sentence |
denotes |
II. |
T83 |
270-321 |
Sentence |
denotes |
Chrome parts should only be wiped with a dry towel. |
T84 |
322-356 |
Sentence |
denotes |
Abrasive polishes are not allowed. |
T85 |
357-405 |
Sentence |
denotes |
Wax is suggested to protect the surface coating. |
T86 |
406-463 |
Sentence |
denotes |
Plastic surfaces can only be cleaned with soap and water. |
T87 |
464-468 |
Sentence |
denotes |
III. |
T88 |
469-554 |
Sentence |
denotes |
Common glass cleaner except for amide products can be used to clean the touch screen. |
T89 |
555-633 |
Sentence |
denotes |
Spray the glass cleaner on the cloth or towel, and then wipe the touch screen. |
T90 |
634-734 |
Sentence |
denotes |
Be sure to remove the liquid drops in time to prevent it from flowing into the gap of the equipment. |
T91 |
736-758 |
Sentence |
denotes |
Equipment disinfection |
T92 |
759-761 |
Sentence |
denotes |
I. |
T93 |
762-933 |
Sentence |
denotes |
After each examination (including X-ray photography, CT, magnetic resonance imaging, or others), the equipment must be disinfected by wiping the surface using 75% ethanol. |
T94 |
934-937 |
Sentence |
denotes |
II. |
T95 |
938-978 |
Sentence |
denotes |
Corrosive disinfectants are not allowed. |
T96 |
979-983 |
Sentence |
denotes |
III. |
T97 |
984-1133 |
Sentence |
denotes |
Disinfectant sprays should be used carefully, as they may penetrate into the equipment, resulting in short-circuit, metal corrosion, or other damage. |
T98 |
1134-1303 |
Sentence |
denotes |
If the spray disinfector is needed in the room, the equipment must be shut down, cooled, and completely covered with plastic film before starting the spray disinfection. |
T99 |
1304-1385 |
Sentence |
denotes |
Then the equipment itself is disinfected by wiping the surface using 75% ethanol. |
T100 |
1387-1405 |
Sentence |
denotes |
Floor disinfection |
T101 |
1406-1615 |
Sentence |
denotes |
Visible pollutants should firstly be removed using disposable water absorption material, and then the floor should be disinfected by using 2000 mg/L disinfectant containing chlorine (except for chlorhexidine). |
T102 |
1616-1731 |
Sentence |
denotes |
Furthermore, any other objects (such as handrail, door handle, window, and wall switch) should also be disinfected. |
T103 |
1733-1749 |
Sentence |
denotes |
Air disinfection |
T104 |
1750-1930 |
Sentence |
denotes |
Air disinfection for the equipment room is recommended by using ultraviolet irradiation (continuous irradiation for more than 30 min), followed by ventilation for more than 30 min. |
T105 |
1932-1950 |
Sentence |
denotes |
Other disinfection |
T106 |
1951-2007 |
Sentence |
denotes |
All disposable protective products must be non-reusable. |
T107 |
2008-2234 |
Sentence |
denotes |
The reusable protective products (such as goggles) should be placed at the designated disinfection place, and be soaked in 1000 mg/L disinfectant containing chlorine (except for chlorhexidine) or 75% ethanol for more than 1 h. |