T276 0-116 Sentence denotes However, in this device, the TCR is not of importance as the metal structure will not be used as temperature sensor.
T277 117-211 Sentence denotes Real-time temperature sensing is done using a thermocouple in the temperature monitor chamber.
T278 212-352 Sentence denotes The resistance of the heater structure changes with temperature; thus, the dissipated power changes when a fixed voltage or current is used.
T279 353-477 Sentence denotes However, the results in Section 3.4 show a 25 h stability test with a constant input potential and only a ±1.5 °C deviation.
T280 478-580 Sentence denotes The TCR can become more important when other (higher) temperatures are required for the amplification.