PMC:7045880 / 3701-4918 JSONTXT 9 Projects

Annnotations TAB TSV DIC JSON TextAE

Id Subject Object Predicate Lexical cue
T37 0-2 Sentence denotes 2.
T38 3-19 Sentence denotes Real-time RT-PCR
T39 20-177 Sentence denotes The optimal concentration of primers and probes, which were synthesized using a published sequence [12], was determined with the RNA transcripts of SARS-CoV.
T40 178-267 Sentence denotes The primer and probe sequences used for RNA-dependent RNA polymerase gene detection were:
T41 268-484 Sentence denotes 5′-GTGARATGGTCATGTGTGGCGG-3′ (Forward), 5′-CARATGTTAAASACACTATTAGCATA-3′ (Reverse) and 5′-CAGGTGGAACCTCATCAGGAGATGC-3′ (Probe in 5-FAM/3′-BHQ format) and the primer and probe sequences used for E gene detection were:
T42 485-636 Sentence denotes 5′-ACAGGTACGTTAATAGTTAATAGCGT-3′ (Forward), 5′-ATATTGCAGCAGTACGCACACA-3′ (Reverse) and 5′-ACACTAGCCATCCTTACTGCGCTTCG-3′ (Probe in 5-FAM/3′-BHQ format).
T43 637-925 Sentence denotes A 25-μL reaction was setup that contained 5 μL of RNA, 12.5 μL of 2 × reaction buffer provided with the Agpath IDTM 1 step RT-PCR system (Thermo Fisher Scientific, Waltham, USA), 1 μL of 25 × enzyme mixture, 1 μL of forward and reverse primers at 10 pM, and 0.5 μL of each probe at 10 pM.
T44 926-1063 Sentence denotes Reverse transcription was performed at 50°C for 30 minutes, followed by inactivation of the reverse transcriptase at 95°C for 10 minutes.
T45 1064-1217 Sentence denotes PCR amplification was performed with 40 cycles at 95°C for 15 seconds and 60°C for 1 minute using an ABI 7500 Fast instrument (Thermo Fisher Scientific).