PubMed:9639536 / 646-885
Annnotations
Glycan-Motif
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
T4 | 81-96 | https://glytoucan.org/Structures/Glycans/G00054MO | denotes | sialyl Lewis(x) |
GlyCosmos6-Glycan-Motif-Image
Id | Subject | Object | Predicate | Lexical cue | image |
---|---|---|---|---|---|
T4 | 81-96 | Glycan_Motif | denotes | sialyl Lewis(x) | https://api.glycosmos.org/wurcs2image/0.10.0/png/binary/G00054MO |
Glycosmos6-GlycoEpitope
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
T4 | 81-96 | http://www.glycoepitope.jp/epitopes/EP0012 | denotes | sialyl Lewis(x) |
GlyCosmos6-Glycan-Motif-Structure
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
T4 | 81-96 | https://glytoucan.org/Structures/Glycans/G00054MO | denotes | sialyl Lewis(x) |
sentences
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
TextSentencer_T5 | 0-239 | Sentence | denotes | A tandem mass spectrometry experiment was designed to detect the presence of the sialyl Lewis(x) antigen based on the observation of an 803 mass to charge ratio ( m/z ) ion produced in the intermediate pressure region of the ESI interface. |
T5 | 0-239 | Sentence | denotes | A tandem mass spectrometry experiment was designed to detect the presence of the sialyl Lewis(x) antigen based on the observation of an 803 mass to charge ratio ( m/z ) ion produced in the intermediate pressure region of the ESI interface. |
T5 | 0-239 | Sentence | denotes | A tandem mass spectrometry experiment was designed to detect the presence of the sialyl Lewis(x) antigen based on the observation of an 803 mass to charge ratio ( m/z ) ion produced in the intermediate pressure region of the ESI interface. |
GlycoBiology-FMA
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
_T10 | 189-201 | FMAID:179268 | denotes | intermediate |
_T11 | 189-201 | FMAID:74531 | denotes | intermediate |
uniprot-human
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
T3 | 225-228 | http://www.uniprot.org/uniprot/P19957 | denotes | ESI |
GO-BP
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
T5 | 81-87 | http://purl.obolibrary.org/obo/GO_0097503 | denotes | sialyl |
GlycoBiology-Motifs
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
T4 | 81-93 | http://rdf.glycoinfo.org/glycan/G00053MO | denotes | sialyl Lewis |
T11 | 81-95 | http://rdf.glycoinfo.org/glycan/G00054MO | denotes | sialyl Lewis(x |
T18 | 88-93 | http://rdf.glycoinfo.org/glycan/G00047MO | denotes | Lewis |
T25 | 88-95 | http://rdf.glycoinfo.org/glycan/G00051MO | denotes | Lewis(x |
GlycoBiology-Epitope
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
PD-GlycoEpitope-B_T4 | 88-95 | http://www.glycoepitope.jp/epitopes/EP0011 | denotes | Lewis(x |
PD-GlycoEpitope-B_T11 | 81-93 | http://www.glycoepitope.jp/epitopes/EP0008 | denotes | sialyl Lewis |
PD-GlycoEpitope-B_T18 | 81-95 | http://www.glycoepitope.jp/epitopes/EP0012 | denotes | sialyl Lewis(x |
Glycan-GlyCosmos
Id | Subject | Object | Predicate | Lexical cue | image |
---|---|---|---|---|---|
T4 | 81-96 | Glycan | denotes | sialyl Lewis(x) | https://api.glycosmos.org/wurcs2image/latest/png/binary/G00054MO |
GlyCosmos-GlycoEpitope
Id | Subject | Object | Predicate | Lexical cue | glycoepitope_id |
---|---|---|---|---|---|
T4 | 81-96 | http://purl.jp/bio/12/glyco/glycan#Glycan_epitope | denotes | sialyl Lewis(x) | http://www.glycoepitope.jp/epitopes/EP0012 |
sentences
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
TextSentencer_T5 | 0-239 | Sentence | denotes | A tandem mass spectrometry experiment was designed to detect the presence of the sialyl Lewis(x) antigen based on the observation of an 803 mass to charge ratio ( m/z ) ion produced in the intermediate pressure region of the ESI interface. |
T5 | 0-239 | Sentence | denotes | A tandem mass spectrometry experiment was designed to detect the presence of the sialyl Lewis(x) antigen based on the observation of an 803 mass to charge ratio ( m/z ) ion produced in the intermediate pressure region of the ESI interface. |
T5 | 0-239 | Sentence | denotes | A tandem mass spectrometry experiment was designed to detect the presence of the sialyl Lewis(x) antigen based on the observation of an 803 mass to charge ratio ( m/z ) ion produced in the intermediate pressure region of the ESI interface. |
GlyCosmos15-Sentences
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
T5 | 0-239 | Sentence | denotes | A tandem mass spectrometry experiment was designed to detect the presence of the sialyl Lewis(x) antigen based on the observation of an 803 mass to charge ratio ( m/z ) ion produced in the intermediate pressure region of the ESI interface. |
GlyCosmos15-Glycan
Id | Subject | Object | Predicate | Lexical cue | glycosmos_id | image |
---|---|---|---|---|---|---|
T4 | 81-96 | Glycan | denotes | sialyl Lewis(x) | https://glycosmos.org/glycans/show/G00054MO | https://api.glycosmos.org/wurcs2image/latest/png/binary/G00054MO |
GlyCosmos15-GlycoEpitope
Id | Subject | Object | Predicate | Lexical cue | glycoepitope_id |
---|---|---|---|---|---|
T4 | 81-96 | http://purl.jp/bio/12/glyco/glycan#Glycan_epitope | denotes | sialyl Lewis(x) | http://www.glycoepitope.jp/epitopes/EP0012 |