PMC:8950092 / 27776-28412 JSONTXT

Annnotations TAB JSON ListView MergeView

{"target":"http://pubannotation.org/docs/sourcedb/PMC/sourceid/8950092","sourcedb":"PMC","sourceid":"8950092","source_url":"https://www.ncbi.nlm.nih.gov/pmc/8950092","text":"Figure 15 shows the average PFU/L Air graphs for all configurations normalized to the stock PFU counts of configuration ‘b’. Comparing the results, adding the air curtain decreases the concentration of particles at the patient’s head and throughout the room in comparison to without the air curtain in configuration ‘b’. Configuration ‘a’ decreased the particle concentration at the patient’s head but had the highest concentration at Sampler A by the door in the hospital test room. Based on the p-value, 0.832, obtained from the ANOVA test, there is no significant difference between the average results from the three configurations.","tracks":[]}