PMC:7443692 / 61098-61372
Annnotations
LitCovid-sample-sentences
{"project":"LitCovid-sample-sentences","denotations":[{"id":"T412","span":{"begin":0,"end":274},"obj":"Sentence"}],"namespaces":[{"prefix":"_base","uri":"http://pubannotation.org/ontology/tao.owl#"}],"text":"Full MS scans were acquired from m/z 200 to 2000 at 60k resolution, and MS/MS scans following higher-energy collisional dissociation (HCD) with stepped collision energy (15%, 25%, 35%) or electron transfer dissociation (ETD) were collected in the Orbitrap at 15k resolution."}
LitCovid-sample-UniProt
{"project":"LitCovid-sample-UniProt","denotations":[{"id":"T5105","span":{"begin":0,"end":4},"obj":"Protein"}],"attributes":[{"id":"A5105","pred":"uniprot_id","subj":"T5105","obj":"https://www.uniprot.org/uniprot/Q8N1N2"}],"text":"Full MS scans were acquired from m/z 200 to 2000 at 60k resolution, and MS/MS scans following higher-energy collisional dissociation (HCD) with stepped collision energy (15%, 25%, 35%) or electron transfer dissociation (ETD) were collected in the Orbitrap at 15k resolution."}
LitCovid-sample-PD-FMA
{"project":"LitCovid-sample-PD-FMA","denotations":[{"id":"T202","span":{"begin":220,"end":223},"obj":"Body_part"}],"attributes":[{"id":"A202","pred":"fma_id","subj":"T202","obj":"http://purl.org/sig/ont/fma/fma67781"}],"text":"Full MS scans were acquired from m/z 200 to 2000 at 60k resolution, and MS/MS scans following higher-energy collisional dissociation (HCD) with stepped collision energy (15%, 25%, 35%) or electron transfer dissociation (ETD) were collected in the Orbitrap at 15k resolution."}
LitCovid-sample-PD-GO-BP-0
{"project":"LitCovid-sample-PD-GO-BP-0","denotations":[{"id":"T128","span":{"begin":188,"end":205},"obj":"http://purl.obolibrary.org/obo/GO_0022904"}],"text":"Full MS scans were acquired from m/z 200 to 2000 at 60k resolution, and MS/MS scans following higher-energy collisional dissociation (HCD) with stepped collision energy (15%, 25%, 35%) or electron transfer dissociation (ETD) were collected in the Orbitrap at 15k resolution."}
LitCovid-sample-GO-BP
{"project":"LitCovid-sample-GO-BP","denotations":[{"id":"T119","span":{"begin":188,"end":205},"obj":"http://purl.obolibrary.org/obo/GO_0022904"}],"text":"Full MS scans were acquired from m/z 200 to 2000 at 60k resolution, and MS/MS scans following higher-energy collisional dissociation (HCD) with stepped collision energy (15%, 25%, 35%) or electron transfer dissociation (ETD) were collected in the Orbitrap at 15k resolution."}