PMC:7164859 / 9781-10334
Annnotations
LitCovid-PubTator
{"project":"LitCovid-PubTator","denotations":[{"id":"184","span":{"begin":123,"end":167},"obj":"Disease"},{"id":"185","span":{"begin":469,"end":521},"obj":"Disease"},{"id":"187","span":{"begin":67,"end":77},"obj":"Species"}],"attributes":[{"id":"A184","pred":"tao:has_database_id","subj":"184","obj":"MESH:D011027"},{"id":"A185","pred":"tao:has_database_id","subj":"185","obj":"MESH:D011027"},{"id":"A187","pred":"tao:has_database_id","subj":"187","obj":"Tax:2697049"}],"namespaces":[{"prefix":"Tax","uri":"https://www.ncbi.nlm.nih.gov/taxonomy/"},{"prefix":"MESH","uri":"https://id.nlm.nih.gov/mesh/"},{"prefix":"Gene","uri":"https://www.ncbi.nlm.nih.gov/gene/"},{"prefix":"CVCL","uri":"https://web.expasy.org/cellosaurus/CVCL_"}],"text":"Table 1 Technical measures for preventing contamination of HCPs by SARS-CoV-2.\nPrefer the “closed” technique for obtaining pneumoperitoneum\nReduce the pneumoperitoneum pressure as much as possible (without compromising safety)\nReduce the power of electrosurgery and ultrasonic dissection\nSystematically use laparoscopic smoke aspiration systems\nSystematically use particle filters\nPrefer intracorporeal anastomosis\nExtract excised tissue after complete emptying of the pneumoperitoneum\nFully aspirate the pneumoperitoneum before removing the last trocar"}
LitCovid-PD-FMA-UBERON
{"project":"LitCovid-PD-FMA-UBERON","denotations":[{"id":"T33","span":{"begin":403,"end":414},"obj":"Body_part"},{"id":"T34","span":{"begin":431,"end":437},"obj":"Body_part"}],"attributes":[{"id":"A33","pred":"fma_id","subj":"T33","obj":"http://purl.org/sig/ont/fma/fma3726"},{"id":"A34","pred":"fma_id","subj":"T34","obj":"http://purl.org/sig/ont/fma/fma9637"}],"text":"Table 1 Technical measures for preventing contamination of HCPs by SARS-CoV-2.\nPrefer the “closed” technique for obtaining pneumoperitoneum\nReduce the pneumoperitoneum pressure as much as possible (without compromising safety)\nReduce the power of electrosurgery and ultrasonic dissection\nSystematically use laparoscopic smoke aspiration systems\nSystematically use particle filters\nPrefer intracorporeal anastomosis\nExtract excised tissue after complete emptying of the pneumoperitoneum\nFully aspirate the pneumoperitoneum before removing the last trocar"}
LitCovid-PD-UBERON
{"project":"LitCovid-PD-UBERON","denotations":[{"id":"T9","span":{"begin":431,"end":437},"obj":"Body_part"}],"attributes":[{"id":"A9","pred":"uberon_id","subj":"T9","obj":"http://purl.obolibrary.org/obo/UBERON_0000479"}],"text":"Table 1 Technical measures for preventing contamination of HCPs by SARS-CoV-2.\nPrefer the “closed” technique for obtaining pneumoperitoneum\nReduce the pneumoperitoneum pressure as much as possible (without compromising safety)\nReduce the power of electrosurgery and ultrasonic dissection\nSystematically use laparoscopic smoke aspiration systems\nSystematically use particle filters\nPrefer intracorporeal anastomosis\nExtract excised tissue after complete emptying of the pneumoperitoneum\nFully aspirate the pneumoperitoneum before removing the last trocar"}
LitCovid-PD-MONDO
{"project":"LitCovid-PD-MONDO","denotations":[{"id":"T24","span":{"begin":67,"end":75},"obj":"Disease"}],"attributes":[{"id":"A24","pred":"mondo_id","subj":"T24","obj":"http://purl.obolibrary.org/obo/MONDO_0005091"}],"text":"Table 1 Technical measures for preventing contamination of HCPs by SARS-CoV-2.\nPrefer the “closed” technique for obtaining pneumoperitoneum\nReduce the pneumoperitoneum pressure as much as possible (without compromising safety)\nReduce the power of electrosurgery and ultrasonic dissection\nSystematically use laparoscopic smoke aspiration systems\nSystematically use particle filters\nPrefer intracorporeal anastomosis\nExtract excised tissue after complete emptying of the pneumoperitoneum\nFully aspirate the pneumoperitoneum before removing the last trocar"}
LitCovid-sentences
{"project":"LitCovid-sentences","denotations":[{"id":"T86","span":{"begin":0,"end":78},"obj":"Sentence"},{"id":"T87","span":{"begin":79,"end":139},"obj":"Sentence"},{"id":"T88","span":{"begin":140,"end":226},"obj":"Sentence"},{"id":"T89","span":{"begin":227,"end":287},"obj":"Sentence"},{"id":"T90","span":{"begin":288,"end":344},"obj":"Sentence"},{"id":"T91","span":{"begin":345,"end":380},"obj":"Sentence"},{"id":"T92","span":{"begin":381,"end":414},"obj":"Sentence"},{"id":"T93","span":{"begin":415,"end":485},"obj":"Sentence"},{"id":"T94","span":{"begin":486,"end":553},"obj":"Sentence"}],"namespaces":[{"prefix":"_base","uri":"http://pubannotation.org/ontology/tao.owl#"}],"text":"Table 1 Technical measures for preventing contamination of HCPs by SARS-CoV-2.\nPrefer the “closed” technique for obtaining pneumoperitoneum\nReduce the pneumoperitoneum pressure as much as possible (without compromising safety)\nReduce the power of electrosurgery and ultrasonic dissection\nSystematically use laparoscopic smoke aspiration systems\nSystematically use particle filters\nPrefer intracorporeal anastomosis\nExtract excised tissue after complete emptying of the pneumoperitoneum\nFully aspirate the pneumoperitoneum before removing the last trocar"}
LitCovid-PD-HP
{"project":"LitCovid-PD-HP","denotations":[{"id":"T9","span":{"begin":326,"end":336},"obj":"Phenotype"}],"attributes":[{"id":"A9","pred":"hp_id","subj":"T9","obj":"http://purl.obolibrary.org/obo/HP_0002835"}],"text":"Table 1 Technical measures for preventing contamination of HCPs by SARS-CoV-2.\nPrefer the “closed” technique for obtaining pneumoperitoneum\nReduce the pneumoperitoneum pressure as much as possible (without compromising safety)\nReduce the power of electrosurgery and ultrasonic dissection\nSystematically use laparoscopic smoke aspiration systems\nSystematically use particle filters\nPrefer intracorporeal anastomosis\nExtract excised tissue after complete emptying of the pneumoperitoneum\nFully aspirate the pneumoperitoneum before removing the last trocar"}
LitCovid-PMC-OGER-BB
{"project":"LitCovid-PMC-OGER-BB","denotations":[{"id":"T128","span":{"begin":67,"end":77},"obj":"SP_7"},{"id":"T122","span":{"begin":67,"end":77},"obj":"SP_7"},{"id":"T123","span":{"begin":123,"end":146},"obj":"UBERON:0001179"},{"id":"T124","span":{"begin":151,"end":167},"obj":"UBERON:0001179"},{"id":"T125","span":{"begin":431,"end":437},"obj":"UBERON:0000479"},{"id":"T126","span":{"begin":469,"end":491},"obj":"UBERON:0006562"},{"id":"T127","span":{"begin":505,"end":521},"obj":"UBERON:0006562"}],"text":"Table 1 Technical measures for preventing contamination of HCPs by SARS-CoV-2.\nPrefer the “closed” technique for obtaining pneumoperitoneum\nReduce the pneumoperitoneum pressure as much as possible (without compromising safety)\nReduce the power of electrosurgery and ultrasonic dissection\nSystematically use laparoscopic smoke aspiration systems\nSystematically use particle filters\nPrefer intracorporeal anastomosis\nExtract excised tissue after complete emptying of the pneumoperitoneum\nFully aspirate the pneumoperitoneum before removing the last trocar"}