
PMC:7152911 / 90068-91084
Annnotations
LitCovid-PD-CLO
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
T591 | 194-201 | http://purl.obolibrary.org/obo/SO_0000418 | denotes | signals |
T592 | 212-219 | http://purl.obolibrary.org/obo/SO_0000418 | denotes | signals |
T593 | 340-344 | http://purl.obolibrary.org/obo/CLO_0001185 | denotes | 2018 |
T594 | 494-499 | http://purl.obolibrary.org/obo/UBERON_0007688 | denotes | field |
T595 | 541-547 | http://purl.obolibrary.org/obo/SO_0000418 | denotes | signal |
T596 | 584-591 | http://purl.obolibrary.org/obo/SO_0000418 | denotes | signals |
T597 | 701-709 | http://purl.obolibrary.org/obo/SO_0000418 | denotes | signal's |
T598 | 757-758 | http://purl.obolibrary.org/obo/CLO_0001020 | denotes | a |
T599 | 780-781 | http://purl.obolibrary.org/obo/CLO_0001020 | denotes | A |
T600 | 848-851 | http://purl.obolibrary.org/obo/CLO_0051582 | denotes | has |
LitCovid-PD-CHEBI
Id | Subject | Object | Predicate | Lexical cue | chebi_id |
---|---|---|---|---|---|
T32737 | 483-486 | Chemical | denotes | ion | http://purl.obolibrary.org/obo/CHEBI_24870 |
LitCovid-PD-GO-BP
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
T38 | 226-235 | http://purl.obolibrary.org/obo/GO_0006810 | denotes | transport |
LitCovid-sentences
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
T732 | 0-136 | Sentence | denotes | Various electrochemical methods can be performed using functionalized electrodes to enable pathogen detection (Bard and Faulkner, 2000). |
T733 | 137-290 | Sentence | denotes | These methods differ in electrode configuration, applied signals, measured signals, mass transport regimes, binding information provided (Thévenot et al. |
T734 | 291-339 | Sentence | denotes | 2001), and target size-selectivity (Amiri et al. |
T735 | 340-346 | Sentence | denotes | 2018). |
T736 | 347-564 | Sentence | denotes | Electrochemical methods used for pathogen detection can be classified as potentiometric, amperometric, conductometric, impedimetric, or ion-charge/field-effect, which often signify the measured signal (Thévenot et al. |
T737 | 565-571 | Sentence | denotes | 2001). |
T738 | 572-624 | Sentence | denotes | The applied signals may be constant or time-varying. |
T739 | 625-779 | Sentence | denotes | The result of the electrochemical method may require analysis of the output signal's transient response, steady-steady response, or a combination of both. |
T740 | 780-902 | Sentence | denotes | A detailed discussion of the aforementioned electrochemical methods has been provided elsewhere (Bard and Faulkner, 2000). |
T741 | 903-1016 | Sentence | denotes | Here, we briefly review the most recent methods employed for pathogen detection using electrochemical biosensors. |
2_test
Id | Subject | Object | Predicate | Lexical cue |
---|---|---|---|---|
32364936-11261847-7713119 | 291-295 | 11261847 | denotes | 2001 |
32364936-29756447-7713120 | 340-344 | 29756447 | denotes | 2018 |
32364936-11261847-7713121 | 565-569 | 11261847 | denotes | 2001 |