> top > docs > PMC:7143804 > spans > 27363-29079 > annotations

PMC:7143804 / 27363-29079 JSONTXT

Annnotations TAB JSON ListView MergeView

LitCovid-PubTator

Id Subject Object Predicate Lexical cue
195 480-483 Chemical denotes H2O
196 653-656 Chemical denotes COC
197 661-664 Chemical denotes H2O
198 847-850 Chemical denotes COC
199 855-858 Chemical denotes H2O
200 1053-1056 Chemical denotes H2O
201 1061-1064 Chemical denotes COC

LitCovid-PD-CLO

Id Subject Object Predicate Lexical cue
T189 1160-1161 http://purl.obolibrary.org/obo/CLO_0001020 denotes a
T190 1351-1352 http://purl.obolibrary.org/obo/CLO_0001020 denotes a
T191 1449-1450 http://purl.obolibrary.org/obo/CLO_0001020 denotes a
T192 1590-1591 http://purl.obolibrary.org/obo/CLO_0001020 denotes a

LitCovid-PD-CHEBI

Id Subject Object Predicate Lexical cue chebi_id
T180 480-483 Chemical denotes H2O http://purl.obolibrary.org/obo/CHEBI_15377
T181 488-491 Chemical denotes COC http://purl.obolibrary.org/obo/CHEBI_53310
T182 653-656 Chemical denotes COC http://purl.obolibrary.org/obo/CHEBI_53310
T183 661-664 Chemical denotes H2O http://purl.obolibrary.org/obo/CHEBI_15377
T184 847-850 Chemical denotes COC http://purl.obolibrary.org/obo/CHEBI_53310
T185 855-858 Chemical denotes H2O http://purl.obolibrary.org/obo/CHEBI_15377
T186 1053-1056 Chemical denotes H2O http://purl.obolibrary.org/obo/CHEBI_15377
T187 1061-1064 Chemical denotes COC http://purl.obolibrary.org/obo/CHEBI_53310
T188 1284-1291 Chemical denotes mixture http://purl.obolibrary.org/obo/CHEBI_60004

LitCovid-sentences

Id Subject Object Predicate Lexical cue
T211 0-97 Sentence denotes In Figure 5, the results of heat transfer simulations of two different heater spacings are shown.
T212 98-222 Sentence denotes The heater width for both geometries is 0.3 mm, while the heater spacing in Figure 5b,c are 0.3 mm and 2.0 mm, respectively.
T213 223-350 Sentence denotes In Figure 6a–d, tables with the results of the full parametric sweep for different heater widths and heater spacings are shown.
T214 351-537 Sentence denotes Figure 6a shows the temperature deviation between the highest and lowest temperature at the top of the chamber, i.e., the second H2O and COC interface (ΔTtopofchamber=Ttop,max−Ttop,min).
T215 538-715 Sentence denotes Figure 6b shows the deviation between the highest and lowest temperature inside the chamber, i.e., between the two COC and H2O interfaces (ΔTacrosschamber=Tbottom,max−Ttop,min).
T216 716-907 Sentence denotes Figure 6c shows the temperature deviation between the highest and lowest temperature at the bottom of the chamber, i.e., the first COC and H2O interface (ΔTbottomofchamber=Tbot,max−Tbot,min).
T217 908-1114 Sentence denotes Figure 6d shows the deviation between the set heater temperature of 30 °C and the lowest temperature at the top of the chamber, i.e., the second H2O and COC interface (ΔTdeviationfromsetT=Theater−Ttop,min).
T218 1115-1292 Sentence denotes As can be seen from the results in Figure 6, a combination of small heater widths and heater spacings will result in smaller temperature differences inside the reaction mixture.
T219 1293-1407 Sentence denotes This is evident as smaller heater spacings will result in a better coverage of the heated area by heater material.
T220 1408-1562 Sentence denotes The smaller heater widths will result in a smaller heater cross-sectional area, and thus can be operated at lower powers, as is evident from Equation (1).
T221 1563-1716 Sentence denotes Resulting in the fact that a densely packed meander structure with small heater widths and small heater spacings can dissipate more heat into the system.