PMC:6194691 / 114403-115026
Annnotations
MyTest
{"project":"MyTest","denotations":[{"id":"30340614-4416991-30706343","span":{"begin":346,"end":349},"obj":"4416991"},{"id":"30340614-1113113-30706344","span":{"begin":369,"end":372},"obj":"1113113"},{"id":"30340614-886334-30706345","span":{"begin":390,"end":393},"obj":"886334"},{"id":"30340614-6504234-30706346","span":{"begin":414,"end":417},"obj":"6504234"},{"id":"30340614-3790989-30706347","span":{"begin":434,"end":437},"obj":"3790989"},{"id":"30340614-26661195-30706348","span":{"begin":460,"end":463},"obj":"26661195"},{"id":"30340614-4094481-30706349","span":{"begin":520,"end":523},"obj":"4094481"},{"id":"30340614-4094481-30706350","span":{"begin":582,"end":585},"obj":"4094481"}],"namespaces":[{"prefix":"_base","uri":"https://www.uniprot.org/uniprot/testbase"},{"prefix":"UniProtKB","uri":"https://www.uniprot.org/uniprot/"},{"prefix":"uniprot","uri":"https://www.uniprot.org/uniprotkb/"}],"text":"Concentrations measured in CSF are, with the exception of glutamine always substantially less, than the concentrations in plasma. Concentrations in ISF are measured by microdialysis with extrapolation to zero flow (see text). If these are correct, ISF concentrations are substantially lower than those in CSF. c cisternal, l lumbar\n1Plum et al. [576]\n2Franklin et al. [577]\n3McGale et al. [578]\n4Hamberger et al. [579]\n5Lerma et al. [580]\n6Dolgodilina et al. [581]\n7Table 8.15 in Davson and Segal [56]\n8Jacobson et al. [582] microdialysis by concentration profile\n9Jacobson et al. [582] microdialysis by recovery of samples"}
2_test
{"project":"2_test","denotations":[{"id":"30340614-4416991-30706343","span":{"begin":346,"end":349},"obj":"4416991"},{"id":"30340614-1113113-30706344","span":{"begin":369,"end":372},"obj":"1113113"},{"id":"30340614-886334-30706345","span":{"begin":390,"end":393},"obj":"886334"},{"id":"30340614-6504234-30706346","span":{"begin":414,"end":417},"obj":"6504234"},{"id":"30340614-3790989-30706347","span":{"begin":434,"end":437},"obj":"3790989"},{"id":"30340614-26661195-30706348","span":{"begin":460,"end":463},"obj":"26661195"},{"id":"30340614-4094481-30706349","span":{"begin":520,"end":523},"obj":"4094481"},{"id":"30340614-4094481-30706350","span":{"begin":582,"end":585},"obj":"4094481"}],"text":"Concentrations measured in CSF are, with the exception of glutamine always substantially less, than the concentrations in plasma. Concentrations in ISF are measured by microdialysis with extrapolation to zero flow (see text). If these are correct, ISF concentrations are substantially lower than those in CSF. c cisternal, l lumbar\n1Plum et al. [576]\n2Franklin et al. [577]\n3McGale et al. [578]\n4Hamberger et al. [579]\n5Lerma et al. [580]\n6Dolgodilina et al. [581]\n7Table 8.15 in Davson and Segal [56]\n8Jacobson et al. [582] microdialysis by concentration profile\n9Jacobson et al. [582] microdialysis by recovery of samples"}