{"target":"https://pubannotation.org/docs/sourcedb/PMC/sourceid/4534144","sourcedb":"PMC","sourceid":"4534144","source_url":"https://www.ncbi.nlm.nih.gov/pmc/4534144","text":"In the second case, 3 baffles were installed on the height of 2, 4 and 8 m from the bottom of the studied incinerator with an angle of 90 °. Fig. 5a, shows the gas motion path in this case. As shown, the large volume of the incoming gas is located adjacent to the heat source. The gas emission leaves the incinerator with a lower speed across a longer path compared to the previous case. In this case, the turbulent flow in the incinerator is stronger than the previous case. The average residence time is 3.5 s. The temperature profile is shown in Fig. 5b, Little changes in the temperature profile are observed. Like the previous case, the heat concentration is observed in the middle of the incinerator. The maximum temperature in this case is 100 °C higher than the previous case. Other studies have shown that longer path incinerator or multiple chamber incinerator can be increased PCB removal rate [15, 26].\nFig. 5 a Schematic motion path of gases in the incinerator for the Case 2, (b) The temperature profile (°C) inside the incinerator for the case 2","divisions":[{"label":"label","span":{"begin":915,"end":921}}],"tracks":[{"project":"TEST0","denotations":[{"id":"26269746-121-127-1455814","span":{"begin":906,"end":908},"obj":"[\"17134732\"]"}],"attributes":[{"subj":"26269746-121-127-1455814","pred":"source","obj":"TEST0"}]},{"project":"2_test","denotations":[{"id":"26269746-17134732-59012432","span":{"begin":906,"end":908},"obj":"17134732"}],"attributes":[{"subj":"26269746-17134732-59012432","pred":"source","obj":"2_test"}]}],"config":{"attribute types":[{"pred":"source","value type":"selection","values":[{"id":"TEST0","color":"#93eca2","default":true},{"id":"2_test","color":"#ec939d"}]}]}}