CORD-19:dc97e1de3b69da13f534f15afdcedbf48064c69d / 123575-123711 JSONTXT

Annnotations TAB JSON ListView MergeView

    CORD-19-Sentences

    {"project":"CORD-19-Sentences","denotations":[{"id":"T20962","span":{"begin":0,"end":136},"obj":"Sentence"}],"namespaces":[{"prefix":"_base","uri":"http://pubannotation.org/ontology/tao.owl#"}],"text":"Place the tip of the catheter so that the needle tip rests in the subcutaneous tissue between the artery and the palpating index finger."}

    CORD-19_Custom_license_subset

    {"project":"CORD-19_Custom_license_subset","denotations":[{"id":"T274","span":{"begin":0,"end":136},"obj":"Sentence"}],"text":"Place the tip of the catheter so that the needle tip rests in the subcutaneous tissue between the artery and the palpating index finger."}

    CORD-19-PD-UBERON

    {"project":"CORD-19-PD-UBERON","denotations":[{"id":"T641","span":{"begin":10,"end":13},"obj":"Body_part"},{"id":"T642","span":{"begin":49,"end":52},"obj":"Body_part"},{"id":"T643","span":{"begin":79,"end":85},"obj":"Body_part"},{"id":"T644","span":{"begin":98,"end":104},"obj":"Body_part"},{"id":"T645","span":{"begin":123,"end":135},"obj":"Body_part"},{"id":"T646","span":{"begin":129,"end":135},"obj":"Body_part"}],"attributes":[{"id":"A641","pred":"uberon_id","subj":"T641","obj":"http://purl.obolibrary.org/obo/UBERON_2001840"},{"id":"A642","pred":"uberon_id","subj":"T642","obj":"http://purl.obolibrary.org/obo/UBERON_2001840"},{"id":"A643","pred":"uberon_id","subj":"T643","obj":"http://purl.obolibrary.org/obo/UBERON_0000479"},{"id":"A644","pred":"uberon_id","subj":"T644","obj":"http://purl.obolibrary.org/obo/UBERON_0001637"},{"id":"A645","pred":"uberon_id","subj":"T645","obj":"http://purl.obolibrary.org/obo/UBERON_0003622"},{"id":"A646","pred":"uberon_id","subj":"T646","obj":"http://purl.obolibrary.org/obo/UBERON_0002389"}],"text":"Place the tip of the catheter so that the needle tip rests in the subcutaneous tissue between the artery and the palpating index finger."}

    CORD-19-PD-MONDO

    {"project":"CORD-19-PD-MONDO","denotations":[{"id":"T351","span":{"begin":66,"end":85},"obj":"Disease"},{"id":"T89017","span":{"begin":66,"end":85},"obj":"Disease"}],"attributes":[{"id":"A351","pred":"mondo_id","subj":"T351","obj":"http://purl.obolibrary.org/obo/MONDO_0006591"},{"id":"A35795","pred":"mondo_id","subj":"T89017","obj":"http://purl.obolibrary.org/obo/MONDO_0006591"}],"text":"Place the tip of the catheter so that the needle tip rests in the subcutaneous tissue between the artery and the palpating index finger."}