PubMed:26162292 3 Projects
Frequency characteristics of neuromagnetic auditory steady-state responses to sinusoidally amplitude-modulated sweep tones.
OBJECTIVE: This study aimed to capture the neuronal frequency characteristics, as indexed by the auditory steady-state response (ASSR), relative to physical characteristics of constant sound pressure levels (SPLs). Relationship with perceptual characteristics (loudness model) was also examined.
METHODS: Neuromagnetic 40-Hz ASSR was recorded in response to sinusoidally amplitude-modulated sweep tones with carrier frequency covering the frequency range of 0.1-12.5kHz. Sound intensity was equalized at 50-, 60-, and 70-dB SPL with an accuracy of ±0.5-dB SPL at the phasic peak of the modulation frequency. Corresponding loudness characteristics were modeled by substituting the detected individual hearing thresholds into a standard formula (ISO226:2003(E)).
RESULTS: The strength of the ASSR component was maximum at 0.5kHz, and it decreased linearly on logarithmic scale toward lower and higher frequencies. Loudness model was plateaued between 0.5 and 4kHz.
CONCLUSIONS: Frequency characteristics of the ASSR were not equivalent to those of SPL and loudness model. Factors other than physical and perceptual frequency characteristics may contribute to characterizing the ASSR.
SIGNIFICANCE: The results contribute to the discussion of the most efficient signal summation for the generation of the ASSR at 0.5kHz and efficient neuronal processing at higher frequencies, which require less energy to retain equal perception.
|
Annnotations
- Denotations: 0
- Blocks: 0
- Relations: 0