Appendix B.2. Cyclic Olefin Copolymer Values for the density (ρCOC = 1020 kg m−3), specific heat (cCOC, see Table A2), and thermal conductivity (κCOC,23°C = 0.17 W m−1 K−1 and κCOC,320°C = 0.24 W m−1 K−1, linear fit in between these point) of TOPAS 6017 COC are obtained via TOPAS Advanced Polymers (TOPAS Advanced Polymers, Farmington Hills, MI, USA). The heat capacity at constant pressure (CP,COC) is calculated assuming a homogeneous body of mass m, via Equation (A5), where COMSOL interpolated linearly in between the points. (A5) CP,COC=cCOC×m Table A2 The specific heat of TOPAS 6017 COC. T c T c [°C] [W m−1 K−1] [°C] [W m−1 K−1] 30 1333 180 2298 70 1538 210 2412 110 1754 250 2539 150 1968 290 2645 160 2047 330 2758 Convective heat loss to the air is also taken into account with Equation (A6), which is often used in simulations [56]. (A6) h=10Wm−2K−1