METHODS Between January 2004 and December 2015, a total of 484 patients underwent valve repair for degenerative disease. A true-sized full annuloplasty ring was implanted in all cases. We analysed the effect of preoperative and intraoperative factors on the postrepair gradient. Additionally, we explored the effect of postrepair gradients on long-term outcomes.