RESULTS Thirty-nine patients (57%) had a total of 62 previous operations. The mean aortic cross-clamp time in isolated cases was 129 ± 41 min. There was 1 conduit-unrelated death. The mean DAH diameter was 22.4 ± 3.7 mm (range, 10–29 mm), the average peak gradient was 14 ± 15 mmHg and the mean aortic regurgitation grade (0.5 = trace, 1 = mild) was 0.6 ± 0.5. The mean effective orifice area (EOA) of 25 mm diameter DAH was 3.07 ± 0.7 cm2. DAH annulus z-values were 1.1 ± 1.1 at implantation and 0.7 ± 1.3 at the last follow-up. The last mean left ventricle ejection fraction and left ventricle end diastolic volume index was 63 ± 7% and 78 ± 16 ml/m2 body surface area, respectively. To date, no dilatation has been observed at any level of the graft during follow-up; however, the observational time is short (140.4 years in total, mean 2.0 ± 1.8 years, maximum 7.6 years). One small DAH (10 mm at implantation) had to be explanted due to subvalvular stenosis and developing regurgitation after 4.5 years and was replaced with a 17 mm DAH without complication. No calcification of the explanted graft was noticed intraoperatively and after histological analysis, which revealed extensive recellularization without inflammation.