Given the air flow velocity and the dimensions of the incinerator as well as the high temperatures, the flow regime is turbulent. Neglecting the net rotating flows, since all changes along the flow and in vertical direction are important, the k-ε turbulence model is a good model for analyzing this problem. The equations required to solve the isothermal gas flow in the incinerator include time-averaged mass and momentum conservation equations [24]: