Major contributing factors for catheter-releated bloodstream infections recognized by our colleagues included critical patients who need multiple venous lines for treatment (n = 42), overt bleeding during the process of CVC placement, prolonged procedure time (n = 23), incomplete disinfection of CVC conector (n = 34), and patients with multiple chronic diseases (n = 30).